Home / Design & testing / Electrical & loop drawings

Design & testing

Electrical & loop drawings

Electrical & loop drawings — What an instrument loop diagram shows, how a 2-wire loop is wired from field to PLC, and why cable screens are earthed at one end only.

Open the example below. Change one item at a time, observe the result, then use the explanation to check your understanding.

Open in simulator

Interactive workspace
How to use this tool

Loading the tool…

Read a loop drawing from field device to receiving channel

Give the field device, terminal block, cable core and receiving channel separate references. A loop sheet follows a signal across physical locations. A process diagram shows its purpose and often omits the intermediate connections.

Try the exercise

Follow one signal across the drawing and record each handover. Work backwards from the receiving channel and compare the references. Circle any transition for which the drawing does not supply a core number or terminal identifier.

Common fault or interpretation error

Confusing a cable number with a core number breaks traceability at a multicore cable. Record both whenever the drawing provides both.

A useful tracing exercise follows a pressure transmitter through junction box JB1 to an analogue input. Put each device or terminal boundary on a separate line. Where the sheet gives terminal numbers, copy them exactly; where it omits a reference, mark it for confirmation. Then read the sheet from the opposite end and see whether you arrive at the same field tag without guessing. If two similar transmitter signals appear at the same strip, add the cable and core references to distinguish them. This exercise tests whether the drawing supports maintenance handover as well as initial installation.

Frequently asked question

Why keep terminal references when the instrument tag already matches?

One instrument may have power, signal, shielding and multiple outputs. A tag identifies the device but cannot uniquely identify the path of every conductor.

A simple practice routine

  1. Identify the supply, the load and the control devices before changing the example. Read the terminal names and compare them with the linked guide.
  2. Make one change, then observe the effect. For a circuit, use the diagram and connection check; for a calculator, check the units and the formula.
  3. Return the example to its original condition and repeat the task. Save or export a project from its Project menu before leaving if you need a permanent copy.

Understand the example

A loop diagram shows every connection of one instrument loop on one sheet: the field device, junction box terminals, multicore cable pairs, marshalling terminals, power supply, fuse and PLC channel, with cable numbers. Technicians use it to install, check and fault-find a loop without tracing the whole panel.

For a loop-powered transmitter, the fused 24 V DC supply goes out on one core to the transmitter positive terminal; the return core from the transmitter negative goes back to the analogue input, and the input returns to 0 V. The transmitter sits in series in the loop and controls the current.

A 3-wire device has separate supply, common and signal cores. A 4-wire device has its own power supply and drives the current itself into a passive input.

Instrument cables usually have an overall or individual screen to reduce interference. The screen is normally earthed at one end only, usually the control panel end, and cut back and insulated at the field end. Earthing both ends can let current flow in the screen when the two earth points are at different potentials, which brings noise into the signal.

Check continuity and insulation of each core, terminal numbers against the drawing, polarity, loop supply voltage, and that the PLC channel type matches the signal. Then inject or simulate 4, 12 and 20 mA and confirm the reading at the HMI.

Open Drawings → Loop drawings, choose LT-101 and change its wiring type in the instrument index. The sheet and its checks update.

Continue learning

Instrument loop diagrams and cable screens

Learning model: follow equipment instructions and applicable local rules for real installations. A simulated check is not installation approval.