Home / Simulators / Security & access control

Simulators

Security & access control

Explore access control, locks and security system connections.

Open the example below. Change one item at a time, observe the result, then use the explanation to check your understanding.

Open in simulator

Interactive workspace
How to use this tool

Loading the tool…

Trace a door request separately from lock state

Separate credential decision, release command and door-position feedback in the door example. A granted access request describes a decision. A lock command and a door contact describe different parts of what happens next.

Try the exercise

Run one permitted request in the training view and record the indicated lock state. Compare with a denied request. Use a state table for request, decision, command and feedback. Mark an unmodeled field explicitly instead of inferring it from the command.

Common fault or interpretation error

Assuming all locks have the same behavior on loss of power confuses fail-safe and fail-secure hardware. Verify the device and applicable egress requirements for real systems.

Treat emergency release and ordinary access decisions as separate design questions. In the classroom, label the operator request, controller output, power state, lock response and door contact on a five-column sheet. If the simulator shows only three of these, leave the other columns marked unobserved. Then compare a permitted entry with a denied entry while holding the starting door position fixed. A learner who infers physical movement from a green indicator alone can be asked which additional observation would confirm that inference. Real egress and life-safety design must follow the authority having jurisdiction.

Frequently asked question

Why can a door stay closed after a valid release command?

A release command and physical movement are different events. A person may not open the door, or feedback may be unavailable. State exactly which point the model displays.

A simple practice routine

  1. Identify the supply, the load and the control devices before changing the example. Read the terminal names and compare them with the linked guide.
  2. Make one change, then observe the effect. For a circuit, use the diagram and connection check; for a calculator, check the units and the formula.
  3. Return the example to its original condition and repeat the task. Save or export a project from its Project menu before leaving if you need a permanent copy.

Understand the example

When a card is presented, the controller checks whether the card is known, whether it is still valid, whether its access level includes this door, and whether the current time is inside the level's schedule. Only if all four pass does it release the lock for a set time and log the event.

A fail-safe lock, such as a magnetic lock, needs power to stay locked. If power is lost, or the fire alarm removes it, the door opens. That is what escape routes need.

A fail-secure lock, such as many electric strikes, stays locked without power and only opens when powered. It protects rooms like server rooms or stores, but such doors must still allow free mechanical exit from the protected side where escape is needed.

A door contact tells the controller whether the door is actually closed. If it opens without a valid card or exit request, the controller raises a "forced" alarm. If it stays open longer than allowed after a valid opening, it raises a "held open" alarm. Cameras can record a clip linked to these events.

Doors on escape routes are released by the fire alarm system, usually by removing power from fail-safe locks through a fire-alarm relay, often backed by a green break-glass unit at the door. Local regulations decide which doors must be released.

Open the Security tab, present different cards, cut the access control power and switch on the test fire signal. Watch which doors open.

Continue learning

Access control: fail-safe and fail-secure locks

Learning model: follow equipment instructions and applicable local rules for real installations. A simulated check is not installation approval.