Home / Simulators / Lighting & photocell

Simulators

Lighting & photocell

Follow a photocell lighting circuit from the supply to the lamps.

Open the example below. Change one item at a time, observe the result, then use the explanation to check your understanding.

Open in simulator

Interactive workspace
How to use this tool

Loading the tool…

Find out whether darkness or a selector requests the lamp

Draw two columns for the sensed lighting condition and the selected operating mode. In automatic operation the sensor contributes to the command. A manual override can produce the same lamp indication through a different control path.

Try the exercise

Record the lamp and contactor in bright and dark simulated conditions. Repeat with the selector changed. Find one pair of states with the same lamp indication but different causes. This separates a useful functional test from simply watching a lamp turn on once.

Common fault or interpretation error

Mixing the sensor supply terminals with its switching output makes the logic hard to interpret. Identify each function from the actual device or model legend.

A useful classroom extension is to give the same final lamp indication to two groups while assigning different selector positions. Ask each group to predict the effect of changing only the light level. The group operating in automatic mode should expect a different response from the manual group. Include enough time for any modeled delay. That comparison demonstrates why a visible output becomes useful evidence only when the operating mode and input state are recorded alongside it.

Frequently asked question

If the lamp stays on, has the photocell failed?

Several conditions give that result. A manual-on selection or a contact that remains closed can keep the load on even when the sensor no longer requests it. Follow the command before diagnosing the sensor.

A simple practice routine

  1. Identify the supply, the load and the control devices before changing the example. Read the terminal names and compare them with the linked guide.
  2. Make one change, then observe the effect. For a circuit, use the diagram and connection check; for a calculator, check the units and the formula.
  3. Return the example to its original condition and repeat the task. Save or export a project from its Project menu before leaving if you need a permanent copy.

Understand the example

Outdoor floodlights and street lights are usually switched by a lighting contactor rather than directly by a switch, because the total current is high and the control should come from several places. A small control circuit energises the contactor coil, and its main contacts switch the line and neutral of the lighting circuit.

A photocell measures the daylight. When the light falls below its switch-on level it closes its output contact; when the light rises above a higher switch-off level it opens again. The difference between the two levels (hysteresis) and a short delay stop clouds, shadows or car headlights from switching the lights on and off repeatedly.

The photocell needs its own supply on terminals such as A1 and A2. If that supply is missing the contact never closes.

A selector switch gives three choices. HAND switches the lights on regardless of the daylight, which is useful for maintenance and testing. 0 keeps them off. AUTO passes control to the photocell. The panel often has a pilot lamp that shows when the contactor is energised.

The switch or contact must always break the line conductor; a switch in the neutral leaves the lamp holders live. LED drivers draw a high inrush current when they switch on, so choose the contactor and the circuit breaker from the manufacturer’s lamp-load tables, not only from the normal current. Earth the metal bodies of the luminaires.

Choose “Lighting control” in the simulator. In AUTO press the day/night button and watch the photocell switch the floodlights after its delay, then try HAND and 0.

Continue learning

Lighting control with a photocell and a HAND–0–AUTO switch

Learning model: follow equipment instructions and applicable local rules for real installations. A simulated check is not installation approval.