Distinguish speed selection from reversal
Mark the low-speed and high-speed paths in two colours on a copy of the simulated diagram. A change of speed selects the motor arrangement shown on that drawing. A motor supplied for a different winding arrangement may need a completely different connection scheme.
Try the exercise
Request low speed, record the active contactors, stop, and repeat at high speed. Check that the incompatible contactor states cannot overlap. Identify the common stop path and one speed-specific permissive. Keep the winding drawing and the control drawing side by side.
Common fault or interpretation error
Treating a terminal number as a universal winding identity can produce a plausible but incorrect diagram. Read the motor-specific connection legend.
When presenting the result to a teacher, provide one table per speed and identify which contactors must be released before the alternate speed can be accepted.
Frequently asked question
Can a reversing-starter diagram be reused as a two-speed diagram?
The control logic may share an interlocking principle, but the power circuits do different things. The motor winding diagram and rating plate determine the appropriate connections for each speed.
A simple practice routine
- Identify the supply, the load and the control devices before changing the example. Read the terminal names and compare them with the linked guide.
- Make one change, then observe the effect. For a circuit, use the diagram and connection check; for a calculator, check the units and the formula.
- Return the example to its original condition and repeat the task. Save or export a project from its Project menu before leaving if you need a permanent copy.
Understand the example
A Dahlander (pole-changing) motor has one three-phase winding with a centre tap in each phase. By changing how the halves are connected, the number of magnetic poles is halved, so the motor runs at two speeds in a ratio of 2:1, for example about 720 and 1440 rpm.
Two-speed motors are common on fans, conveyors and machine tools where two fixed speeds are enough and a variable frequency drive is not needed.
For LOW speed the supply goes to terminals 1U, 1V and 1W and the winding works in delta, with 2U, 2V and 2W left open. For HIGH speed the supply goes to 2U, 2V and 2W, and a third contactor links 1U, 1V and 1W together. This turns the winding into a double star (YY).
So a typical starter has three contactors: KM1 for low speed, KM2 for high speed and KM3 for the star bridge. KM3 closes first and KM2 is fed through an auxiliary contact of KM3, so the motor never receives high-speed voltage without its star point.
Inside a Dahlander winding the phase order seen on the high-speed terminals is reversed compared with the low-speed terminals. To make the motor turn the same way at both speeds, two supply phases are swapped on the high-speed contactor. If they are not swapped, the motor reverses when it changes speed, which can damage the machine.
The low-speed contactor must never close together with the high-speed or star-bridge contactors: that would short-circuit the supply through the winding. Each coil circuit therefore passes through normally-closed auxiliary contacts of the other contactors.
The current is different at each speed, so there are two overload relays, each set to the nameplate current for its own speed, with both 95-96 contacts in series in the control circuit.
Choose “Two-speed motor” in the simulator, run at low speed, stop, then run at high speed and watch KM3 close before KM2. The Check tab tests that both speeds turn forward.
Continue learning
Learning model: follow equipment instructions and applicable local rules for real installations. A simulated check is not installation approval.